Aircraft Electrical Systems Explained: Busbars, Generators and Load Shedding (EASA ATPL)

How a twin-jet electrical system is built so no single failure leaves you dark: 400 Hz alternators, constant-speed drives, TRUs, the battery, busbar hierarchy, split operation and load shedding — and the traps EASA sets.

Aircraft Electrical Systems Explained: Busbars, Generators and Load Shedding (EASA ATPL)

Aircraft Electrical Systems Explained: Busbars, Generators and Load Shedding (EASA ATPL)

Night, IMC, and a generator drive fails. On the flight deck, almost nothing changes — and that is the point.

A transport aircraft's electrical system is not designed to be clever. It is designed so that no single failure — a generator, a drive, a busbar, a cable — can ever leave the crew in the dark. For EASA ATPL Aircraft General Knowledge (021), electrics is a guaranteed block of questions, and the logic behind it is always the same: sources, conversion, distribution, protection.

The fast version: engine-driven alternators produce 115/200 V, 400 Hz, three-phase AC through constant-speed drives. Transformer rectifier units convert part of it to 28 V DC. Busbars distribute it in a hierarchy — main, essential, emergency — and in cruise the two sides run split, with the bus tie breaker open. The battery is the source of last resort, roughly 30 minutes of essential power. Everything else is protection.

Built around failure, not efficiency

Every design choice in an aircraft electrical system starts from the same question: what happens when this component dies? The answers shape the whole architecture:

  • Multiple independent sources. Two engine-driven generators, an APU generator, external power on the ground, and a battery — so that electrical power never depends on a single machine.
  • Segregation. The left and right sides of the system are electrically separated in flight, so a fault on one side cannot drag down the other.
  • A hierarchy of loads. Some equipment is nice to have; some keeps the aeroplane flyable. The distribution system knows the difference and sheds the former to protect the latter.

Hold those three ideas and most exam questions answer themselves.

The sources: AC first, DC where it is needed

Engine-driven alternators are the primary sources. A modern transport alternator is a three-phase AC machine producing 115 V phase / 200 V line at a constant 400 Hz. Two numbers here are exam bait:

  • Why 400 Hz and not the 50/60 Hz of ground power? Higher frequency allows smaller, lighter magnetic components — generators, transformers and motors shrink dramatically. Weight is everything on an aircraft, and 400 Hz is the compromise between component size and transmission losses.
  • Why "constant"? Engine rpm varies continuously, but the frequency must not. Between the engine gearbox and the alternator sits a constant-speed drive (CSD) — or an integrated drive generator (IDG), which packages the CSD and alternator in one unit — holding alternator speed, and therefore frequency, constant across the whole engine range.

AC is efficient to generate and distribute, but plenty of aircraft equipment wants DC. That conversion is the job of the transformer rectifier unit (TRU): it steps 115/200 V AC down and rectifies it to 28 V DC. A TRU converts — it never generates — a distinction examiners test every year.

The battery — typically a 24 V lead-acid or nickel-cadmium unit — does two jobs: starting (APU or engines) and last-resort standby power. In normal flight it is kept charged by the DC system and does essentially nothing. Its moment comes when everything else is gone: the battery feeds the essential loads for a certification-intended endurance of about 30 minutes. The classic Ni-Cd hazard to know is thermal runaway: heat lowers internal resistance, which raises charging current, which makes more heat — a loop that can destroy the battery if charging is not properly controlled.

Around the edges: the APU generator can substitute for a main generator on the ground or in flight, external power feeds the buses on the turnaround, and a small static inverter turns battery DC into AC for the few essential AC instruments when only the battery remains.

Distribution: the busbar hierarchy

Power reaches users through busbars — distribution bars, each feeding a family of circuits. The hierarchy reflects how much each load matters:

A twin-jet split-bus electrical system Normal cruise state: bus tie breaker open — each generator feeds only its own side

ENG GEN 1 115/200 V · 400 Hz · 3-phase

APU GEN / EXT PWR backup or ground source

ENG GEN 2 115/200 V · 400 Hz · 3-phase

AC BUS 1 AC BUS 2

BUS TIE BREAKER — NORMALLY OPEN (split operation) closes automatically or manually to power both sides from one source

ESS / STANDBY BUSES fed first, shed last · inverter → ESS AC

TRU 1 AC → 28 V DC TRU 2 AC → 28 V DC

BATTERY 24 V source of last resort ≈ 30 min

DC BUS 1 DC BUS 2

DC tie

Lose GEN 1: BTB closes, GEN 2 (or APU) powers both sides. Lose everything: the battery holds the essential buses.

Split operation in cruise: each constant-speed-drive generator powers its own AC bus with the bus tie breaker open; TRUs convert AC to 28 V DC for the DC buses, and the battery stands behind the essential buses as the last-resort source. Diagram: ATPL Training.

In cruise, a twin-jet normally runs split (non-parallel) operation: each alternator feeds only its own AC bus, and the bus tie breaker (BTB) between them is open. Why not parallel them onto one big bus, like power stations do? Because parallel operation needs fine control of real and reactive load sharing — and, far worse, a serious fault on a paralleled system can take out both generators at once. Split operation contains every failure to one side. If a generator does fail, the BTB closes and the remaining generator — or the APU generator — powers both sides.

Load shedding is the final layer of the logic. When available power drops, the system (or the crew) sheds non-essential loads — galleys, in-flight entertainment, some cabin services — so that everything that keeps the aircraft flying stays powered. Essential buses are fed first and shed last.

Protection: fuses, breakers and cut-outs

Every circuit is protected so that a fault disconnects the circuit, not the system:

  • Circuit breakers are resettable switches that trip on excess current. The exam point that never dies: a circuit breaker protects the wiring, not the equipment at the end of it — it is rated to the cable, and it trips after a time delay that depends on the fault current.
  • Fuses do the same job once, by melting. A fuse is generally faster than a breaker at very high fault currents — another favourite distractor pair.
  • Current limiters are heavy-duty fuses protecting major feeder cables, changed only on the ground.
  • The reverse-current cut-out watches each generator: if generator voltage falls below battery voltage, current would reverse and the battery would motor the generator, discharging itself. The cut-out opens the generator line contactor automatically. Same logic as the BTB: a failed source is isolated before it can hurt the healthy side.

The traps EASA sets on this topic

  • "A TRU generates 28 V DC." It converts, never generates. Any option saying a TRU produces power is wrong.
  • "The bus tie breaker is normally closed in cruise." It is open — split operation is the normal state; the BTB closes only to reconfigure after a source failure.
  • "400 Hz AC improves transmission efficiency." The driver is weight: smaller, lighter generators, transformers and motors.
  • "The battery powers the aircraft in normal flight." The generators do. The battery starts things and then waits for the day everything else fails.
  • "Circuit breakers protect the equipment." They protect the wiring. Equipment protection is a side effect, not the design rating.

EASA ATPL electrics: FAQ

Why do aircraft use 400 Hz AC?

Because generator, transformer and motor size shrinks as frequency rises. At 400 Hz the magnetic components are far smaller and lighter than at 50/60 Hz — a decisive weight saving — while transmission losses remain acceptable over an aircraft's short cable runs.

Is the bus tie breaker open or closed in normal flight?

Open. A twin normally runs split operation, each alternator powering its own AC bus, so a fault stays contained on one side. The BTB closes to let one source power both sides after a generator failure, or when the APU generator or external power is feeding the system.

How long can the battery power the aircraft?

The certification intent is about 30 minutes of essential loads — enough to get on the ground — with non-essential consumers long since shed. It is a glider-range reserve, not a second generator.

What is the difference between a CSD and an IDG?

A constant-speed drive (CSD) is the hydromechanical unit between engine gearbox and alternator that holds alternator speed — and therefore the 400 Hz frequency — constant as engine rpm varies. An integrated drive generator (IDG) packages the CSD and the alternator into a single unit on the gearbox.